TATSU
The TATSU is a rapid exchange catheter with a seven-cup balloon for pre-and post-dilatation of the coronary arteries. The unique design of the catheter and balloon, the use of modern materials and an innovative hydro¬philic coating provide an excellent combination of working properties of the catheter and rapid inflation/ deflation time of the balloon. The TATSU combines the competitive features of an ideal workhorse balloon dilatation catheter.

Product Features
Diameter | 1.50mm to 4.00mm |
Balloon length | 10mm - 40mm |
Usable length | 138 cm |
Nominal pressure | 8 bar |
RBP | up to 19 bar |
- Very low entry profile with a bevelled tip to cross the most difficult lesions
- Maximum flexibility for easy navigation to reach the most distal lesions
- Fast inflation and deflation times to maximize efficiency during treatment and reducing the procedure time
- Increased pushability for a significant force transition from hub to tip
- High rated burst pressure to optimize working range
GENBU
There is still continued innovation in the bare metal coronary stents systems. Qmedics strategy includes in their product innovations always the compliance with the movability of the artery, the lesion characteristic and clinical efficiency. The Genbu is an innovative balloon expandable Cobalt-chromium coronary stent system of the latest generation.

Product Features
Diameter | 2.25mm - 6.00mm |
Stent Length | 8mm - 38mm |
Stent Material | Cobalt-Chromium (L605) |
Usable Length | 138 cm |
Nominal Pressure | 8 bar |
RBP | up to 19 bar |
O GONCHO
O Goncho Sirolimus-Eluting Coronary Stent System is a device/drug combination. A Cobalt Chromium alloy platform that is superior in radial strength, thinner strut thickness, high tractability and flexibility and a systemic elution of sirolimus in a well -controlled fashion after the stent implantation.

Product Features
Diameter | 2.25mm - 4.00mm |
Stent Length | 8mm - 48mm |
Usable Length | 138 cm |
Nominal Pressure | 8 bar |
RBP | up to 19 bar |
Cobalt Chromium | Strut thickness: 65 µm |
Strut thickness: | 65 µm |
Coating thickness: | 3-5 µm |
Metal-artery ratio: | 15 % - 18 % |
Balloontip profile: | 0.017” (0.43mm) |
Lowestcrossing profile: | 0.035” (0.90mm) |
Recoil: | >2 % |
BAKU
In the past few years, some successor devices for treating coronary heart disease CHD have emerged. Undoubtedly, drug-coated balloons (DCB), which were recommended by the ESC Guidelines on myocardial revascularization, are the “shining stars”.

Product Features
Diameter | 2.00mm to 4.00mm |
Balloon length | 10 to 30mm |
Usable length | 138 cm |
Nominal pressure | 7 bar |
RBP | up to 13 bar |