Our Product Range

    TATSU

    The TATSU is a rapid exchange catheter with a seven-cup balloon for pre-and post-dilatation of the coronary arteries. The unique design of the catheter and balloon, the use of modern materials and an innovative hydro¬philic coating provide an excellent combination of working properties of the catheter and rapid inflation/ deflation time of the balloon. The TATSU combines the competitive features of an ideal workhorse balloon dilatation catheter.

    TATSU

    Product Features

    Diameter 1.50mm to 4.00mm
    Balloon length 10mm - 40mm
    Usable length 138 cm
    Nominal pressure 8 bar
    RBP up to 19 bar
    • Very low entry profile with a bevelled tip to cross the most difficult lesions
    • Maximum flexibility for easy navigation to reach the most distal lesions
    • Fast inflation and deflation times to maximize efficiency during treatment and reducing the procedure time
    • Increased pushability for a significant force transition from hub to tip
    • High rated burst pressure to optimize working range
    Order Now

    GENBU

    There is still continued innovation in the bare metal coronary stents systems. Qmedics strategy includes in their product innovations always the compliance with the movability of the artery, the lesion characteristic and clinical efficiency. The Genbu is an innovative balloon expandable Cobalt-chromium coronary stent system of the latest generation.

    GENBU

    Product Features

    Diameter 2.25mm - 6.00mm
    Stent Length 8mm - 38mm
    Stent Material Cobalt-Chromium (L605)
    Usable Length 138 cm
    Nominal Pressure 8 bar
    RBP up to 19 bar
    Order Now

    O GONCHO

    O Goncho Sirolimus-Eluting Coronary Stent System is a device/drug combination. A Cobalt Chromium alloy platform that is superior in radial strength, thinner strut thickness, high tractability and flexibility and a systemic elution of sirolimus in a well -controlled fashion after the stent implantation.

    O GONCHO

    Product Features

    Diameter 2.25mm - 4.00mm
    Stent Length 8mm - 48mm
    Usable Length 138 cm
    Nominal Pressure 8 bar
    RBP up to 19 bar
    Cobalt Chromium Strut thickness: 65 µm
    Strut thickness: 65 µm
    Coating thickness: 3-5 µm
    Metal-artery ratio: 15 % - 18 %
    Balloontip profile: 0.017” (0.43mm)
    Lowestcrossing profile: 0.035” (0.90mm)
    Recoil: >2 %
    Order Now

    BAKU

    In the past few years, some successor devices for treating coronary heart disease CHD have emerged. Undoubtedly, drug-coated balloons (DCB), which were recommended by the ESC Guidelines on myocardial revascularization, are the “shining stars”.

    BAKU

    Product Features

    Diameter 2.00mm to 4.00mm
    Balloon length 10 to 30mm
    Usable length 138 cm
    Nominal pressure 7 bar
    RBP up to 13 bar
    Order Now